﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	blockedby	blocking	notify_on_close	platform	project
7491	Make --cmd startup option behave like executing a script in its treatment of semi-colons	christian.tueting@…	Tom Goddard	"Christian noted that the shell --cmd option in ChimeraX where several commands are given separated by semi-colons does not update volume surfaces between commands.  This is because no graphics is rendered between the commands and the surface is only updated when it is drawn.  In command scripts (.cxc files) the volumes are updated immediately.  It would be good to change the the --cmd option so it treats those commands as a command script.

Here is Christian's original description of the problem on the ChimeraX mailing list:

{{{
From: Christian Tüting
Subject: [chimerax-users] Measure volume at multiple threshold levels not function
Date: August 17, 2022 at 3:54:40 AM PDT
To: <chimerax-users@cgl.ucsf.edu>

Dear ChimeraX-Team,

I have an issue with the volume measure tool. I would like to measure the volume at different thresholds.
Using the gui mode, I can type the following:

volume #1 level 1
measure volume #1
LOG: Enclosed volume for surface (#1.1) = 4.012e+06

volume #1 level 2
measure volume #1
LOG: Enclosed volume for surface (#1.1) = 2.144e+06

So this is functional in principle. But I would like to run this in no gui mode, so the commands are "";"" seperated. 


But, even in gui mode, I got the following:

(threshold was set to 1 before executing)

volume #1 level 1; measure volume #1
LOG: Enclosed volume for surface (#1.1) = 4.012e+06

volume #1 level 2; measure volume #1
LOG: Enclosed volume for surface (#1.1) = 4.012e+06

So the threshold level is not applied, prior to the measurement of the volume. 

And this is the same in the no-gui mode. I would like to check the volume at 5 different levels, but I got always the same value when executing:

""/usr/libexec/UCSF-ChimeraX-daily/bin/ChimeraX --nogui --cmd 'open cryosparc_P42_J241_002_volume_map_sharp.mrc; volume #1 level 0.5; measure volume #1.1; volume #1 level 0.5; measure volume #1.1; volume #1 level 0.5; measure volume #1.1; volume #1 level 1; measure volume #1.1; volume #1 level 1; measure volume #1.1; volume #1 level 1; measure volume #1.1; volume #1 level 1.5; measure volume #1.1; volume #1 level 1.5; measure volume #1.1; volume #1 level 1.5; measure volume #1.1; volume #1 level 2; measure volume #1.1; volume #1 level 2; measure volume #1.1; volume #1 level 2; measure volume #1.1; volume #1 level 2.5; measure volume #1.1; volume #1 level 2.5; measure volume #1.1; volume #1 level 2.5; measure volume #1.1' --exit""


Is there any command, that the threshold level is somehow applied, and the measure volume is executed correctly?

The problem is present in
UCSF ChimeraX version: 1.4.dev202202240543
and
UCSF ChimeraX version: 1.5.dev202207221833

Best
Christian
}}}"	defect	closed	moderate		Input/Output		fixed		Elaine Meng				all	ChimeraX