Subject: Re: [nmr_sparky] resonance panels?
From: Tom Goddard
Date: Apr 20, 2010

Previous: 677 Next: 682


Hi Jessie,

The Sparky resonance panels dont allow you to specify which resonances you want to choose. You can reduce the number of resonances shown by enabling Filter resonance panels (rf) in the View settings dialog (vt). What this does is use the filtering defined by the assignment guessing tool (ag). So, for example for an HSQC the assignment guessing settings might say that the w1 axis and w2 axis for a peak assignment should have the same residue number (i - i) and this will limit the display of resonances in the panels when you are looking at a subregion of the HSQC to only those that could be used in a possible i-i assignment in the displayed area of the spectrum.

Tom

Greetings, I am new to Sparky and was previously using Felix. A feature I enjoyed was being able to display the frequencies of a specific residue like grids on any of the other spectra (assigned or unassigned). Is there such a feature in Sparky?

The closest thing I have found is displaying the resonance panels. However, I cant seem to filter down to the resonances of just a single residue without altering window size and aspect ratio. Is there a better way to do this?

Thanks,
Jessie