Subject: 回覆: [nmr_sparky] Combining 'prot' files f rom 3D 15N NOESY and 13C NOESY
From: LIU Changdong
Date: May 25, 2007

Previous: 375 Next: 377


hi,
open the project which contains all the sprctrums (have been assigned)
type rl
then save as *.shifts,maybe you need have a check.

for the noesy spetrum, you just need write out *.peaks file. its not necessary to write out *.shifts file(it has been written out from rl command) from noesy spectrum

hope this helpful

best

Dr. S. Vivekanandan vivek_subra@... 說:
Dear Sparky Users,

1. I have analysed all the backbone and sidechain peaks using
backbone and sidechain experiments.

2. I analysed 3D 15N-NOESY and created chemical shift files and peak
file (xe command - click write shifts (filename.prot) , and click
write peaks (filename.peaks)

3. I analysed 3D 13C-NOESY and created chemical shift files and peak
file (xe command - click write shifts (filename.prot) and click
write peaks-(filename. peaks)

I use CYANA formy structural calculation.

The chemical shift files (filename.prot ) that I derived from 13C
NOESY and 15N NOESY contains different numbers for the same atoms.
This creates problem while running CYANA as the assignment is
different due to two different prot files. I combined two prot
files into one using all_prot.cya which basically combines all the
chemical shifts to one file. But still I am unable to use both my
15N NOESY constaraints and 13C-NOESY constraints together. Can any
one suggest me the solution to this kind of problems I face in
SPARKY. Many Thanks,

Vivekanandan Ph.D



現在你可輕易阻擋垃圾郵件,立即使用Yahoo! Mail 你就會相信!